Wall Assemblies USG provides resources here for our UL wall assemblies for seamless integration into any construction project. These wall assembly files are used for planning and estimation purposes for many UL wall types, such as fire-rated wall assemblies. Have a Question About Assemblies? Call: 1-800-USG-4YOU Contact Tech Support
The Cavity Shaft Wall System includes components that provide the strength to withstand lateral loads and fire protection necessary for walls that enclose elevator shafts, stairwells and other
Horizontal Shaftwall - Georgia-Pacific Building Products
Horizontal Shaftwall Designed for ceiling or duct shaft and composed of 1" (25.4 mm) ToughRock® Shaftliner or DensGlass® Shaftliner panel supported by 2-1/2" (64 mm), 4" (102 mm) or 6" (152 mm) C-T studs and three layers of 1/2" (12.7 mm) ToughRock® Fireguard C® or 1/2" (12.7 mm) DensArmor Plus® Fireguard C® gypsum board. Hourly Rating: 2-hour
UL Assemblies Directory, Architectural Design Drawings | USG
Assemblies Directory & Design Details USG offers professionals a complete set of architectural drawings for planning and estimation. Whether you need exterior design detail drawings or interior design detail drawings, make the most informed decisions with our comprehensive UL assemblies directory and UL assembly details.
USG Shaft Wall Systems are non-load-bearing gypsum wall partition assemblies constructed from outside the shaft at each floor. Shafts are enclosed early in
Gyprock Shaft Systems are not suitable for certain walls of Class 9B buildings which require 1.0kPa loading. Resistance to Impact A series of impacts from a 27.2kg sandbag are imposed on a typical wall section and must not cause permanent damage.
Design Your System 21 Design Details Good Design Practices Specify Your System 33 Application Guide Specifications For More Information Technical Service 800 USG.4YOU Websites Use USG shaft wall systems to construct elevator shafts, mechanical shafts, stairwells, air return shafts and horizontal membranes. These shafts are
USG CH Shaftwall Stud 34 mil "CH" studs are fabricated in web depths of 2-1/2″, 4″, and 6″ each with a short-flange width of 1-3/8″ and long-flange width of 1-1/2″. All C-H studs manufactured by CEMCO are produced from hot-dipped galvanized steel in standard G40 coating. G60 is available upon special request.
Partiwall® Separating Wall System - Knauf Australia
Partiwall® is a twin stud wall system, which incorporates a single or double layer 25mm Shaftliner™ Mouldstop plasterboard fire barrier within the wall cavity. Shaftliner panels are held in position by lightweight steel H- or I-section studs. Installation of Shaftliner fire barrier is carried out during the framing stage and does not require
USG Shaft Walls provide up to 4-hour fire resistance and sound ratings to 51 STC. They resist intermittent lateral loads up to 15 psf; also resist fatigue
OVERVIEW CGC Shaft Wall Systems are non-load-bearing gypsum wall partition assemblies constructed from outside the shaft at each floor. Shafts are enclosed early in construction, and
PDF USG Shaft Wall Systems - Architectural Builders Supply Inc.PDF
USG shaft wall systems are non-loadbearing gypsum wall partition assemblies constructed from outside the shaft at each floor. Shafts are enclosed early in construction, and the walls are finished later, along with interior partitions. Installation is quick and easy, using components and application procedures familiar to drywall contractors.
USG Shaft Wall Systems are non-load-bearing gypsum wall partition assemblies constructed from outside the shaft at each floor. Shafts are enclosed early in construction, and the walls are finished later, along with interior partitions. Installation is quick and easy, using components and application procedures familiar to drywall contractors.
USG Middle East Shaftwall Access Panel - Heavy Duty is ideal for for shaftwall, plum walls and brick wall installation, comes with mounting claws for simple wall installation. Add To Favorites Add to Compare Heavy Duty Shaft Wall Wet Area Size Product Identifier Qty Order Sample Add To My Project List Performance Specifications Product Items
The Purple Book II | Commercial Construction Details - National
Find commercial construction details including wall assemblies. The PURPLE Book II PDF General Information PDF Steel Stud Partitions PDF Shaftwall Assemblies PDF Stair Shaftwall Details PDF Elevator Shaftwall Details PDF Shaftwall Repair Details PDF
Building Product: USG Shaft Wall System [10313b8] - ARCAT
Mill Steel Framing is a licensed manufacturer of the USG Shaft Wall system. USG Shaft Wall Systems are non-load-bearing gypsum wall partition assemblies
USG STEEL J-RUNNER 1" SHEETROCK BRAND GYPSUM LINER PANEL USG STEEL C-H STUD 1 Shaft Wall-AER-09038 SCALE: DATE: UNITED STATES GYPSUM COMPANY This Shaft Wall Detail must not be used without a complete evaluation by the owner's design professional--to verify the suitability of the design for a given structure.
USG Cavity Shaft Wall System - Product Data - BuildSite
Design Your System 23 Design Details Good Design Practices Specify Your System 36 Application Guide Specifications For More Information Technical Service 800 USG.4YOU Websites usg.com usgdesignstudio.com 4 USG Shaft Wall Systems shaft at
A 2-hour fire-resistive, non-load bearing non-combustible partition designed to enclose shaftwalls, containing elevators, ducts, piping, air shafts and similar construction applications. System consists of 1" shaftliner panels supported by 2-1/2", 4" or 6" C-T studs and faced on one side with two layers of 1/2" Type C or 5/8" Type X gypsum board.
PDF USG Floor Slab Penetration Details Fire Resistant Assemblies - J2132PDF
disclaimer: the usg product details contained herein are intended for use as product reference material by architects, engineers, other design professionals, fire resistant assemblies head of wall details usg j2132 rev 0 issued 10/19/2015. scale: 3" = 1' - 0" 2 hr head of wall ul hw-d-0627 1 scale: 3" = 1' - 0" 2 hr head of wall ul hw-s-0001 4
Design Details Details Page - USG Head of Shaft Wall Details
USG Head of Shaft Wall Details CAD - J2131 USG Head of Shaft Wall Details CAD - J2131 More Need Help? Contact Us Samples Inquiries Media Inquiries Customer Service (Sales) 1
Leave Reply